Towers

Lighting Masts Down-Town Motorway Junction Bremen (G) (2017, operational dynamic behavior, damping, Modal Analysis, together with baudyn GmbH Hamburg (G))

San Luzi, Zuoz, Bell Tower (2004/09/11/12/13/14, Modal Analyses, operational dynamic behavior, 16-month’s vibration and environmental parameter’s monitoring)

Wind Turbines envergate ev600, Gossau SG (2010, Modal Analysis, 1-week-Monitoring)

Wind Turbines Pumar, Spain (2010, Modal Analysis)

Peter und Paul, Zürich, Bell Tower (2002/04, Modal Analysis, Operational dynamic behavior)